When fixing edge gutter to timber fascia ensure the bracket is secured using a minimum of two self as required to ensure correct fit.
Gutter edge detail.
Tpa 207 tremline edge detail with extender tpa 211 gravel stop with tpa coated metal tpa 213 gravel stop tpa coated metal isometric tpa 220 through wall scupper detail 8 4 8.
If there is a gutter water leaving the lower roof edge is directed into the gutter not behind it not down building walls not where we don t want it to go.
Make sure you don t skip any fact.
If there is no gutter water leaves the edge and zooms out into space away from the building.
The straps should extend a minimum of 6 onto the roof.
The brown drip edge is properly installed and is doing its job.
As part of the es 1 testing protocol re 3 tests upward and outward simultaneous pull of a horizontal and vertical flanges of a parapet coping cap.
Demonstrated to perform in accordance with as nzs 3500 this solution a ords the bold striking lines of edge gutter whilst still meeting overfl ow requirements.
Straps are riveted or bolted to the outer edge at the gutter bead and attached to the roof with two brass screws.
Gutter clip edge gutter is the epitome of form and function.
Detailed drawings single ply tpa 221 through wall scupper isometric tpa 222 gravel stop scupper detail tpa 232 gutter detail tpa 301 parapet wall flashing detail 8.
Difference between gutter apron vs drip edge.
After knowing each one in detail we are going to compare the main differences between the gutter apron and the drip edge.
This is a typical detail of a gutter hung by straps.
For corner details cut the top edge and also a v shape in the trough at the bottom edge of the trim.
The gutter is supported by brackets spaced 30 o c.
Strap hung molded gutter.
It cannot be installed on an existing roof.
The external edge of the gutter must be terminated with a wall termination detail.
The flashing strips for the gutter extend a minimum of 200 mm at the internal edge of the gutter so as to provide sufficient overlap for a batten in the seam detail.
This excess can be folded around and glued or attached to the side of the roof edge with a hammer tacker.
Low slope metal perimeter edge details include fascia coping and gutters are critical systems that can strongly impact the long term performance of single ply roofs.
3 9 4 internal gutters are to be flashed with separate strips of epdm membrane.
If necessary non standard eaves braces can be fabricated to suit individual cases.
A gutter apron is not recommended if a gutter is far from the edge of the shingles.
Eaves beams and purlins should be selected from their respective load tables.
Maintenance requirements the performance of edge gutter over time depends on its correct application and maintenance.
An excess of membrane at the gutter edge corners needs to be tidied up and secured.